Get Quote

Jiangsu Sfere Electric Co., Ltd

News

  • Warm Congratulations to Elecnova Energy Storage Xirun Semiconductor 2.4MWh ESS Project for Its Successful Grid Connection!
    Continuing the series of projects providing energy storage solutions (BESS) for customers. Recently, Elecnova has provided the ESS battery storage system to the Semiconductors semiconductor factory. Elecnova's ESS solution makes a very important contribution to maintaining continuous production for the factory and helps save energy for this Semiconductors factory. The project uses advanced energy storage technology and equipment, which is efficient, stable and safe. During the construction and operation of the entire project, we pay attention to details, strictly control every link, continuously optimize the design plan, improve equipment performance, and ensure the smooth progress of the project. Ultimately, we successfully connected the energy storage system to the grid, bringing more stable and reliable power services to our customers and society as a whole. At the same time, the project can also promote the use and development of renewable energy and promote energy transformation and sustainable development. BESS project for Semiconductors factory: Capacity: 2.4MWh Battery type: Lithium-iron ion Application: Provides backup power, reduces electricity costs, and uses energy effectively   Result: Minimize energy waste Increase power reliability by 99.9% Save electricity costs by 5% Minimize CO2 emissions   Benefits for Semiconductors manufacturing plants: Improve production efficiency Minimize the risk of production disruption Save operating costs Enhance company image Elecnova is a leading BESS solution provider with many years of experience. We provide BESS solutions tailored to customers' diverse needs. Contact Elecnova today for specific advice on BESS solutions for your factory: Phone: 0086-19906165606 / 021-54396121 Email: sales@elecnova-ess.com Shanghai Elecnova Energy Storage Co., Ltd. #BESS #Elecnova #Semiconductors #Renewable Energy #Production Efficiency #Cost Savings

    2024 04/24

  • Introducing the Latest Innovation in Energy Measurement: The Multi-function Smart Meter
    In today's fast-paced world, the demand for energy efficiency is higher than ever. To meet this growing need, a revolutionary new product has been introduced - the multi-function smart meter. This cutting-edge device not only measures electricity consumption, but also offers a range of advanced features designed to help consumers better manage their energy usage. The multi-function smart meter combines traditional energy measurement capabilities with state-of-the-art technology to provide users with real-time data on their electricity usage. By tracking and analyzing this data, consumers can gain valuable insights into their energy habits and identify areas where they can reduce consumption and save money. But that's not all - the multi-function smart meter goes beyond simple energy monitoring. It also offers a range of additional features, such as remote access and control capabilities, allowing users to monitor and adjust their electricity usage from anywhere, at any time. This level of convenience and control is unprecedented in the world of energy measurement, and is sure to revolutionize the way we think about managing our energy consumption. In addition, the multi-function smart meter is designed to be user-friendly and easy to install. With its sleek, modern design and intuitive interface, it's never been easier to take control of your energy usage and start saving money on your electricity bill. Overall, the multi-function smart meter represents a major step forward in the world of energy measurement. By combining traditional metering capabilities with advanced technology and user-friendly design, this innovative device is set to change the way we think about managing our energy consumption. Get ready to take control of your energy usage like never before with the multi-function smart meter.  

    2024 04/02

  • DC multi function power meter for communication iron tower and PV solar power plant
    Brief introduction  Direct current(DC) meters have had a comparatively low proportion in the use of power measuring instruments due to their unique usage scenarios. In recent years, the rise of the renewable energy industry such as PV solar power plant and wind power plant, communication iron tower for base station, and the booming energy storage industry drives a tremendous demand for DC multifunctional power meters. In this article you could find the general introduction about the application of ELECNOVA PD195Z-E31/E33 DC power meter.   PD195Z-E31 is available for a single DC circuit measuring, provides U/I/P/kWh, demand and extreme value, PD195Z-E33 maximum  measuring and monitoring 21 DC circuits U/I/P, TOU(Multi-tariff) and kWh(energy consumption). By connecting with the EK1 external D/I module, the PD195Z-E31 can achieve the digital input and relay output functions. It also equipped with a RS485 communication interface for the data integration and with the power management system and energy management system.           Advantages  Multiple current sensing Multi tariff (TOU) Plenty external module(LORA、DI/DO、NB-IoT) External module Plug-in installation & auto-ID       Model Selection            Typical Wiring            Installation             Application  Communication Iron Tower base station Solar PV power plant Power storage system

    2024 03/21

  • Celebrating Elecnova's successful participation in the 2024 KEY Energy Exhibition in Rimini, Italy.
    From February 28th to March 1st, 2024, the KEY Energy Italy International Energy Exhibition was grandly held at the Rimini Exhibition Center in Italy. KEY Energy is the largest, most influential, and most renowned renewable energy exhibition in Southern Europe, attracting over 1500 exhibitors. The Italian Minister of Energy personally attended the event, and several media outlets reported on the exhibition. Sfere Electric, with its subsidiary Elecnova Energy Storage, made a brilliant appearance at the exhibition, showcasing the ECO series of air-cooled integrated cabinets, liquid-cooled integrated cabinets, energy storage containers, as well as supporting products such as PCS, BMS, and EMS.     During the three-day exhibition, Elecnova's energy storage products attracted a lot of attention from the European energy storage industry and agents due to their mature product design, complete system support, and diverse collaboration concepts. Many enterprise representatives visited the booth for in-depth discussions with exhibitors to explore cooperation opportunities.       The high professionalism and industry influence of the KEY Energy exhibition not only attracted participation from internationally renowned companies like Huawei but also hosted a series of energy industry seminars and product launches, providing a positive and effective communication platform for domestic and foreign exhibitors and visitors. Through this exhibition, Sfere Electric gained a more comprehensive understanding of the application of energy storage products in the European market. The Elecnova energy storage team maintained real-time communication throughout, promptly responded to customer needs, and rapidly developed solutions, providing strong service support for the first overseas energy storage event in 2024.     The KEY Energy exhibition showcased significant market potential for the European energy storage industry. With a professional team, strong cohesion, and firm execution, Sfere Electric and Elecnova Energy Storage are poised to rapidly grow into a shining new star in the energy storage industry.

    2024 03/01

  • SFERE-Small circuit breaker SFB5TMA-63 series
    Introduction SFB5TMA-63 single magnetic circuit breaker (hereinafter referred to as circuit breaker) is mainly suitable for power distribution networks with AC 50Hz/60Hz, rated current 1A to 63A, and rated voltage 230V or 400V. It is suitable for low-voltage terminal power distribution in medical IT power distribution systems, motor protection and building fire protection systems. As a short-circuit protection switch, it can also be used with thermal relays or motor starters to achieve overload protection. Dimensions

    2024 02/18

  • A must-have tool for photovoltaic power plants, SFERE SDP-5100F5-G series device function integration
    01 Introduction The SDP-5100F5-G series anti-islanding protection device has powerful function integration, exquisite structure, large-screen LCD display, graphical Chinese menu, and four-way navigation panel. It is fast and convenient to operate. It is suitable for switch cabinets, box-type substations, and photovoltaics below 35kV. power station. This series of devices integrates multiple functions such as protection, measurement, control, monitoring, communication, and event recording. The device is equipped with 8 switching inputs and 7 relay outputs, and can store 256 SOE event records in a loop, which will not be lost when the power is off. 02 Features Complete protection functions Reverse power protection Automatic closing under pressure Device power loss alarm 03 Application Photovoltaic power station Box type substation Intelligent power distribution system Intelligent switch panel wind farm

    2024 01/16

  • Application of Sfere Elecnova Power Quality Products in the National Food Safety Hengqin Innovation Center Project
    The National Food Safety (Hengqin) Innovation Center project is located in Hong Kong Macao Avenue, Hengqin New District, Zhuhai City. Covering an area of approximately 86000 square meters, construction area of about 250,000 square meters. The overall structure consists of nine main buildings, divided into two office buildings, three modular office buildings, and four apartments. The center focuses on building a high-end industrial park that integrates business, office, commercial blocks, and apartments. Only by ensuring safe, continuous, and reliable high-quality electricity resources can enterprise users have a safer, more reliable, and efficient electricity consumption experience, significantly improving operational and production efficiency, and achieving high-quality development of the park. The application of nonlinear power equipment (frequency converters, UPS, switching power supplies, etc.) in industrial and household electrical loads is becoming increasingly widespread, and such equipment will generate a large amount of harmonics. According to the load characteristics, the project adopts a power quality management scheme of SVG static var generator+SFR-M intelligent dynamic harmonic suppression reactive power compensation module, ensuring the stability of the entire power supply system. SFR-SVG static var generator module and SFR-M harmonic suppression compensation module are integrated and installed in the same cabinet for coordinated control. The main body uses SFR-M compensation and SVG compensation is finely used, making the product more cost-effective. The four major advantages are as follows: Intelligent operation: Full response time is less than 10ms, fully modular design, flexible combination. Intelligent and flexible: The intelligent monitoring module can automatically adjust the output ratio of SVG/ passive module according to the dynamic requirements of the system, while meeting the requirements of compensation. Flexible Smoothing: Completely linear, dynamic output, smooth and stable, with a power factor always maintained at 0.99, neither over compensated nor under compensated. Self-diagnosis: It can monitor the real-time status of capacitors, avoiding the capacitor "working with disease" and extending the service life. Product characteristics Flexible application solution Modular design, convenient for expansion, reducing investment waste in the early stage. Reliable communication mode, achieving seamless connection between SVG and SFR-M compensation module communication. Comprehensive equipment and system protection Equipment external electrical fault protection, including busbar short circuit, overvoltage/undervoltage, over/underfrequency, phase sequence error, current reverse sequence, etc. Equipment internal fault protection, including overcurrent protection, IGBT overheating protection, etc. Automatic capacity reduction when the working environment exceeds the limit. Software and hardware current limiting. Resonance avoidance, automatically moving away from the system resonance point. Superior filtering performance Multiple compensation modes can be selected to achieve on-demand distribution of harmonic elimination, reactive power compensation, and unbalanced current compensation. Full range reactive power compensation. A comprehensive three-phase imbalance strategy to achieve active/reactive/split phase imbalance compensation. Three level main circuit, lower power consumption and higher efficiency. The full response time is less than 10ms, and the control is faster, which is beneficial for improving transient stability. Humanized human-machine interaction experience Interactive options include a 7-inch or 10-inch LCD touch screen. Through the graphical display interface, users can clearly understand the improvement of power quality in the system before and after equipment operation, such as waveform diagram, harmonic spectrum diagram, THDi, THDu, effective value of current, power factor, etc. Product parameter Scheme typical design Dynamic filtering compensation device

    2024 01/09

  • What IP Protection tells
    IP protection system is to classify electrical appliances according to their characteristics of dust and moisture prevention. It refers to what environmental conditions electrical equipment is suitable for (such as instruments, lighting equipment, installation materials) and how to protect users from potential hazards. For the adaptability of different environments, the IP protection degree standard has divided corresponding IP codes. IP protection degree is composed of two numbers. The first number indicates the degree of protection against contact and the entry of solid foreign objects. The following table describes the meaning of the first digit of the IP degree: Digit Degree of protection against physical contact Protection degree of solid foreign objects 0 Unprotected Unprotected 1 Prevent large part of human body from entering (diameter 50mm) Prevent large solid foreign objects from entering (diameter ≥ 50mm) 2 Finger entry prevention (diameter 12mm) Prevent medium-size solid foreign objects from entering (diameter ≥ 12.5mm, length ≤ 80mm) 3 Prevent tools and metal wires from entering (diameter ≥ 2.5mm) Prevent small solid foreign objects from entering (diameter ≤ 2.5mm) 4 Prevent tools, wire and fine wire from entering the diameter ≥1mm) Prevent the entry of solid particles and foreign matters (diameter ≤ 1mm) 5 Wire protection (like IP4), dust protection Dust accumulation (harmless) 6 Wire protection (like IP4), dust protection Dust cannot enter The second digit indicates the degree of protection against liquids. The following table describes the meaning of the second number of IP code. Digit Waterproof protection 0 Unprotected 1 Protection against vertical dripping 2 Protection against direct splashing water within 15 degrees from the vertical direction 3 Protection against direct splashing water within 60 degrees from the vertical direction 4 Protection against spray water in any direction 4k It has protection against pressurized spray water in any direction, and only applies to road vehicles 5 Protection against low pressure jet water in any direction 6 Protection against huge waves or strong jet water (water injection) 6k It has protection (water injection) against pressurized strong jet water, and only applies to road vehicles 7 Protection against short immersion in water 8 Protection against long-term immersion in water 9k Protects against high-pressure steam injection, only for road vehicles Note: Each protection level should be considered separately. High protection level does not automatically have low protection level. Introduction to IP protection test 1. Scope Waterproof test includes * * with characteristic numbers of 1 to 8, i.e. protection degree code of IPX1 to IPX8 2. Waterproof test contents of various degree (1) IPX1 Method name: vertical drip test Test equipment: drip test device and its test method Sample placement: place the sample on a rotating table with a speed of 1 r/min according to its normal working position, and the distance from the top of the sample to the drip opening is not more than 200 mm Test conditions: the water drop is 1.0+0.5 mm/min; Test duration: 10min (2) IPX2 Method name: inclined 15 ° drip test Test equipment: drip test device and its test method Sample placement: make one side of the sample form an angle of 15 ° with the vertical line, and the distance from the top of the sample to the drip opening is not more than 200 mm. After each side is tested, change the other side for four times Test conditions: the water drip is 3.0+0.5 mm/min; Test duration: 4 × 2.5 min, 10 min in total (3) IPX3 Method name: rain test A. Pendulum type water spraying test Test equipment: Pendulum type water spray test Sample placement: select a pendulum tube with appropriate radius, make the height of the sample table at the position of the diameter of the pendulum tube, place the sample on the sample table, make the distance from its top to the sample spray nozzle not more than 200mm, and the sample table does not rotate. Test conditions: water flow is calculated according to the number of spray holes in the swing pipe, and each hole is 0.07L/min. When spraying water, the water from the spray hole in the 60 ° arc section on both sides of the midpoint of the swing pipe is sprayed to the sample. Place the sample at the center of the semicircle of the pendulum tube. The swing tube swings 60 ° along both sides of the vertical line, a total of 120 °. Each swing (2 × 120 °) for about 4s. Test pressure: 400kPa; Test time: continuous watering for 10min; The sample rotates 90 ° after 5 min of test B. Sprinkler type water spraying test Test equipment: hand-held water spraying and splashing test device, Sample placement: make the parallel distance from the top of the test to the handheld nozzle between 300mm and 500mm Test conditions: baffle with balance weight shall be installed during the test, and the water flow is 10L/min Test time: 1min per square meter (excluding the installation area), * 5min less, calculated according to the surface area of the tested sample housing. (4) IPX4 Method name: splash test; A. Pendulum type splash test Test equipment and sample placement: select a pendulum tube with appropriate radius, make the height of the sample table at the position of the diameter of the pendulum tube, place the sample on the sample table, make the distance from its top to the sample spray nozzle not more than 200mm, and the sample table does not rotate. Test conditions: water flow is calculated according to the number of spray holes in the swing pipe, and each hole is 0.07L/min; The water spray area is the water spray hole in the 90 ° arc section on both sides of the midpoint of the swing pipe. Place the sample at the center of the semicircle of the pendulum tube. The swing tube swings 180 ° along both sides of the vertical line, about 360 ° in total. Each swing (2 × 360 °) for about 12s. Test time: the same as that in Clause a of IPX3 in Clause (3) above (i.e. 10min). B. Nozzle type splash test Test equipment: hand-held water spraying and splashing test device, Sample placement: the baffle with counterweight installed on the equipment shall be removed so that the parallel distance from the top of the test to the spray nozzle of the handheld nozzle is between 300mm and 500mm. Test conditions: baffle with balance weight shall be installed during the test, and the water flow is 10L/min. Test time: it is 1min per square meter (excluding the installation area) * 5min less, calculated according to the surface area of the tested sample housing. (5) IPX4K Test name: pressurized pendulum tube rain test Test equipment: pendulum tube rain test Sample placement: select a pendulum tube with appropriate radius, make the height of the sample table at the position of the diameter of the pendulum tube, place the sample on the sample table, make the distance from its top to the sample spray nozzle not more than 200mm, and the sample table does not rotate. Test conditions: water flow is calculated according to the number of spray holes in the swing pipe, and each hole is 0.6 ± 0.5L/min. The water spray area is the water spray hole in the 90 ° arc section on both sides of the midpoint of the swing pipe. Place the sample at the center of the semicircle of the pendulum tube. The swing tube swings 180 ° along both sides of the vertical line, about 360 ° in total. Each swing (2 × 360 °) for about 12s. Test pressure: 400kPa Test time: sample rotates 90 ° after 5 min of test Note: The spray pipe has 121 holes with diameter of 0.5mm; --1 hole in the center --2 layers of core area (12 holes in each layer, distributed at 30 degrees) --4 outer rings (24 holes per ring, 15 degree distribution); --Removable cover. The spray pipe shall be made of copper zinc alloy (brass). (6) IPX5 Method name: water spray test Test equipment: inner diameter of spray nozzle is 6.3mm Test conditions: the distance between the test sample and the water spray nozzle is 2.5~3m, and the water flow is 12.5 L/min (750 L/h); Test time: 1min per square meter (excluding the installation area) * 3min less, calculated according to the surface area of the shell of the tested sample. (7) IPX6 Method name: strong water spray test; Test equipment: the inner diameter of the spray nozzle is 12.5mm; Test conditions: the distance between the test sample and the water spray nozzle is 2.5~3m, and the water flow is 100L/min (6000L/h); Test time: 1min per square meter (excluding the installation area) * 3min less, calculated according to the surface area of the shell of the tested sample. D=6.3mm waterproof protection grade 5 and 6K; D=12.5mm waterproof protection grade 6. (8) IPX7 Method name: short-term immersion test; Test equipment: immersion tank. Test conditions: the size shall be such that the distance from the bottom of the sample to the water surface is at least 1m after the sample is put into the immersion tank. The distance from the top of the sample to the water surface shall be at least 0.15m. Test time: 30min. (9) IPX8 Method name: continuous diving test; Test conditions and test time of test equipment: to be agreed by both parties. The severity shall be higher than IPX7. (10) IPX9K Method name: high-pressure injection test Test equipment: the inner diameter of the spray nozzle is 12.5mm; Test conditions: water spray angle: 0 °, 30 °, 60 °, 90 ° (4 positions); Number of spray holes: 4; Rotating speed of sample table: 5 ± 1 r.p.m; The distance is 100~150 mm, and each position is 30 seconds; The flow is 14~16L/min, and the water spray pressure is 8000~ 10000kPa, water temperature requirement 80 ± 5 ℃ Test time: 30 seconds at each position × 4 120 seconds in total. In industrial production, the enclosure protection degree of automatic instrument equipment is an important indicator to ensure the normal operation of equipment and the safety and reliability of the products. During the purchase process, you can confirm the product parameters with us. For example, our conventional power instruments are high-precision and highly reliable intelligent power distribution instrument products designed for power system, industrial and mining enterprises, public facilities, smart buildings and other applications of power monitoring, intelligent control, measurement and assessment. The panel protection level is generally IP54 and some panel mount power quality analyzer can reach IP64 for its front panel. Such as Elecnova digital power analyzer Sfere720, which can fulfil variety request for the industrial and commercial applications.

    2023 12/04

  • Sfere Electric Participated in the 2023 Guangdong Building Electrical And Intelligent Annual Conference
    On November 2, 2023, the 2022 Guangdong Building Electrical & Intelligent Annual Conference, which was postponed due to the epidemic, was grandly held in Guangzhou. The conference is jointly organized by the Architectural Electrical Professional Committee of Guangdong Civil Engineering and Architecture Society and the Guangdong Architectural Electrical Design Technology Cooperation and Information Exchange Network. The theme of this annual conference is "dual carbon goals, intelligent safety". More than 600 representatives from design units, consulting units, drawing review agencies, installation companies, construction units, and electrical and intelligent product production enterprises in Guangdong Province gathered together. Sfere Electric attended the conference to exchange ideas and learn, and jointly discussed hot topics in building electrical and intelligent technology. In addition, nearly 9,900 people watched the conference online. During the conference, Sfere Electric showcased a series of products and solutions for motor protection controllers, power quality monitoring devices, and electrical fire monitoring systems. From time to time, professional personnel from enterprises, construction engineering, installation companies, construction companies, and other related parties visit the Sfere booth to communicate with us in real-time about related issues. Realizing the "dual carbon" goal is a common responsibility of all industries. Smart energy conservation has become the future development trend of China's construction electrical industry. Throughout its comprehensive innovation and technological progress, research and development, and market dual wheel drive, Sfere Electric has provided customers with a comprehensive solution of electrical components+modules+systems+equipment integration, striving to become a top digital intelligent distribution solution supplier in the industry.

    2023 11/17

  • Multifunctional Power Meter Revolutionizes Energy Monitoring
    In the era of smart homes and energy efficiency, the introduction of the multifunctional power meter promises to revolutionize the way we monitor and manage energy consumption. This cutting-edge device is set to empower homeowners and businesses alike with real-time data and insights into their electricity usage. Traditionally, power meters were limited to a single purpose – recording the overall energy consumption of a building. However, the multifunctional power meter takes it a step further by providing a comprehensive overview of various electrical parameters. From voltage and current measurements to power factor and frequency analysis, this versatile device offers a complete picture of energy utilization. One of the key advantages of the multifunctional power meter is its ability to measure and display data in real-time. Users can easily access accurate and up-to-date information about their energy consumption, allowing them to make informed decisions regarding energy-saving strategies. Additionally, the device can be integrated with smart home systems, enabling users to control and monitor their energy usage remotely through a mobile app or web interface. Furthermore, the multifunctional power meter goes beyond simply measuring energy consumption. It also offers advanced features such as load profiling, which helps identify peak usage periods and optimize energy distribution. This data-driven approach encourages efficient energy management, leading to reduced costs and environmental impact. Another noteworthy feature is the power meter's compatibility with renewable energy sources. As more households and businesses embrace solar panels and wind turbines, the device becomes an essential tool for monitoring the generation, consumption, and storage of renewable energy. This integration promotes sustainable practices and encourages the transition towards a greener future. In terms of installation and usability, the multifunctional power meter boasts user-friendly interfaces and easy integration with existing electrical infrastructures. It is designed to be compatible with both single-phase and three-phase systems, catering to a wide range of residential and commercial applications. With its multifunctionality, real-time monitoring capabilities, and compatibility with renewable energy sources, the multifunctional power meter is set to transform the way we understand and manage energy usage. By empowering individuals and businesses with accurate data and insights, this innovative device will undoubtedly play a significant role in achieving a sustainable and energy-efficient future.

    2023 10/23

  • 4 Steps to Chose the Right Reactive Power Compensation Controller
    Did you have ever face the headache when you making the reactive power compensation solution? When you`re going to make a one-stop solution to your customer for power factor correction and you got very limit information. How could a practical power factor correction solution could be came out in short term? In this article , you should only need to use 4 steps to get the answer. Elecnova SLG series reactive power compensation controller is composed of filter reactor and self-healing capacitor, which has the characteristics of remarkable compensation effect, long service life, saving investment and quick effect. It can not only improve the power factor of the distribution system, but also reduce the line loss, suppress harmonics, and improve the safe operation of the entire distribution network. Functional characteristics Accurate reactance rate matching; Reactance capacitors are designed for harmonics to adapt to more complex operating conditions; Design based on actual compensation capacity, with high capacitance withstand voltage; Capacitors have self-healing function, high reliability, and low switching inrush current; The reactor comes with temperature protection terminals, with complete protection functions; The reactor adopts vacuum dipping and hot curing, which has high stability and is safe and noiseless. Model description SLG 50 - P7 / 400 SLG: Product model 50: Compensation capacity(kvar) P7: Reactance coefficient 7% / 14% 400: Rated voltage Technical Parameter Installation instructions Note: 1. When switching the contactor, the temperature protection terminal (normally closed) on the reactor is connected in series to the contactor control coil. 2. When switching to a thyristor or composite switch, the temperature protection terminal on the reactor is connected in series in the common terminal circuit of the composite switch or switching switch. 3. The product should have good ventilation and heat dissipation conditions during operation. 4. It is recommended to place the reactance above the capacitor during installation to facilitate heat dissipation. Model selection (Taking 7% reactance as an example)

    2023 10/13

  • Hybrid Power Quality Compensation For The Lushan Hospital Project
    The construction project of the new Hospital of Lushan County People's Hospital in Pingdingshan City, Henan Province is one of the ten livelihood projects in Lushan County. The new hospital covers an area of 185 mu, with a building area of 140000 square meters, including the ward building, outpatient medical technology building, logistics support building and other buildings. It has 1200 beds and 1500 parking spaces. The total investment is estimated to be RMB 660 million. In the process of modern hospital construction, all kinds of energy-saving lighting equipment, variable frequency air conditioning, elevator equipment, UPS, EPS and various advanced medical equipment are nonlinear equipment. These nonlinear equipment will generate a large number of high power harmonics during operation. Especially, advanced medical equipment has computer components and a large number of highly sensitive microelectronic devices, which require high power quality of power supply, It is very sensitive to voltage fluctuations and power harmonics. The generated harmonics will cause certain interference to the operation of the distribution system and medical equipment. Serious power harmonics problems will cause damage to medical equipment and even medical accidents, affect the medical technology presentation and service embodiment of the hospital, and bring many inconvenience to patients. In order to prevent this kind of situation, our reactive power compensation and active filter devices are used in the project to ensure the safe and reliable operation of electric equipment. Project application Low-voltage reactive compensation controller: WGK-31-203 Introduction WGK-31-203 uses AC sampling algorithm and advanced control algorithm to switch SFR-M, a harmonic suppression type low-voltage power capacitor module, in order to improve the power factor of the grid. Functional characteristics Real-time measurement of voltage, current, power factor, active power, reactive power, harmonic voltage, harmonic current, frequency, capacitor switching state, temperature and other parameters; Flexible switching, supporting manual/automatic switching mode; RS485 interface, Modbus-RTU communication protocol. Low-voltage harmonic suppression reactive compensation module: SFR-M Introduction SFR-M series intelligent dynamic harmonic suppression low-voltage power capacitor module, is specifically aimed at 0.4kV low-voltage distribution network harmonic pollution in the occasion of harmonic and power factor problems, to achieve power factor improvement, harmonic effective suppression, reduce line loss, improve the quality of the integrated reactive power compensation products. In this scheme, a combination of matched controllers is used for harmonic control to solve the harmonic problem, which plays a crucial role in the safe operation of production equipment. At the same time, effective control schemes will bring great value to users. Power quality management module: SFR-APF series active harmonic filter modules Introduction SFR-APF series active filter module is a new type of power electronic device used for dynamic harmonic filtering and reactive power compensation. It can filter and compensate harmonic and dynamic reactive power in real time, and the full response time is less than 5ms. The products are widely used in power metallurgy, petroleum, port, chemical industry, industry and mining and other industries. The CT is used to collect the load current signal, and the harmonic part is separated through the internal detection circuit, and then the PWM signal is sent to the internal IGBT power converter to generate the compensation current with the same size and opposite phase as the system harmonic, so as to realize the real-time dynamic filtering function. Product characteristics Flexible application scheme Modular design, convenient for expansion, up to 16 modules in parallel Rack-mounted or wall-mounted modules, suitable for various installation environments Three-phase three-wire, three-phase four-wire optional, redundant N-wire terminal blocks, maximum adaptability to the site environment CT installation position is flexible, both power supply side and load side Excellent harmonic filtering performance The maximum filtering frequency is 51st , and the harmonic filtering rate is greater than 97% Multiple compensation modes can be selected to realize active harmonic filter, reactive power compensation, unbalanced current compensation distribution on demand Full range reactive compensation Perfect three-phase unbalance strategy to realize active/reactive/split-phase unbalance compensation Three-level main circuit, lower power consumption and higher efficiency The full response time is less than 5ms, and the control is faster, which is beneficial to the improvement of transient stability Perfect equipment and system protection Equipment external electrical fault protection, including bus short circuit, voltage over and under voltage, over and under frequency, phase sequence error, current reverse sequence, etc Equipment internal fault protection, including overcurrent protection, IGBT overheat protection, etc Automatic derating when the working environment exceeds the limit Software and hardware current limiting Resonance avoidance, automatically away from the system resonance point Humanized human-machine interaction experience Interactive optional 7-inch or 10-inch LCD touch screen Through the graphical display interface, users can clearly understand the system waveform diagram and harmonic spectrum diagram Power quality improvement of THDi, THDu, effective value of current, power factor, etc Product standard "Active Power Filter Device" JB/T11067-2011 "Parallel Active Power Filtering Device for Building Electrical Applications" JG/T417-2013 "Communication low-voltage Shunt Active Power Filter" YD/T2323-2011

    2023 09/27

  • Sfere Electric Power Monitoring System Helps Dongben Integrated Smart Factory
    The key project "Dongben Integration" in Guangdong Province invested and constructed by Dongfeng Honda Auto Parts Co., Ltd. will be completed in Dayawan District, Huizhou. With a total investment of 4.5 billion yuan, the project will build 1.5 to 2 million complete vehicle parts and components, covering an area of 420,000 square meters. With the core values of helping customers create value, sharing value with employees, and dedicating value to the society, Jiangsu Sfere Electric Co., Ltd. and Dongfeng Honda jointly assist smart factories and accelerate transformation and upgrading. Sfere Electric relies on a modern management system, with advanced process equipment as a guarantee, uses an efficient information management system, and provides customers with the most valuable cooperation platform with excellent research and development, high-quality products and perfect services. At present, the third phase of Dongfeng Honda Company has been launched, with the goal of completing the overall relocation in September 2019. By then, Dongfeng will be fully built into a modern green project integrating "casting, forging and machining" with an annual production capacity of 2 million vehicles. Sfere Electric customized a set of stable, reliable and technologically advanced power monitoring system for Dongfeng Honda, and integrated smart meters, electrical fire monitoring and intelligent control devices in the smart factory to ensure the smooth operation of the project. In the new factory of "Dongben Integration", Sfere Electric's intelligent power monitoring system and electrical fire monitoring system are used. Intelligent power monitoring system and electrical fire monitoring system are relatively independent systems with their own independent hardware and operating software. They can also upload data to the superior management platform through network connection to realize data sharing. Products helped by Sfere Software and hardware equipment included in the intelligent power monitoring system; Software and hardware equipment included in the power monitoring system; the software and hardware equipment included in the electrical fire monitoring system, and completes the connection, installation and debugging of the monitoring equipment. Project configuration In the design of the drawing, the multi-functional power meter PD194Z-9HY and integrated protector are configured on the circuit of the distribution cabinet in each distribution room where the power monitoring instrument is required to be installed, so as to monitor the current and voltage of a single circuit in real time, and then connect to the communication management machine in each distribution room. After the completion of the system, the communication management machine of each distribution room is pulled to the main control room of the main building through optical fiber through photoelectric converter, and all monitoring data is transmitted to the background of the power monitoring system. Other equipments with digital communication interface, such as temperature control equipment of transformer, DC equipment, analog screen, etc., need to upload data to background computer for remote monitoring or control. Network topology diagram The whole network acquisition structure of the system is to communicate with the main control room through the fiber TP/IP network in each distribution room, to complete the centralized data collection and processing. The network is divided into upper layer network and bottom network. The upper layer network is the Ethernet (or optical fiber Ethernet) from each sub-station to the control center. Industrial-grade optical fiber transceivers are used for photoelectric conversion between the optical fiber and each management device. The bottom network is the RS485 communication cable between instruments, protection and other equipment, which is laid with dedicated twisted pair. Since the communication management machine is configured in their respective sub-stations, the RS485 transmission distance is all within the sub-station, so there will be no long-distance signal interference and attenuation. The equipment layer on the network site mainly includes measuring instruments and protection devices, which are installed in corresponding switch cabinets locally, and have local operation function and are not affected by the start and stop of remote computer. The system consists of three layers from the bottom to top: equipment terminal layer, network communication layer and system management layer. Implementation function It can automatically collect and intelligently manage the electric energy information of all kinds of metering points in the high-voltage distribution room and low-voltage distribution room of the whole plant, so that the distribution network can operate in the best state of safety, reliability, high quality and high efficiency; realize the remote measurement, control and management of distribution network, realize the demand of power safety, power management, energy saving and consumption reduction. By monitoring the residual current, load current and other parameters in the circuit, it can realize the alarm and monitoring of the protected electrical circuit, and upload it to the fire monitoring system to realize centralized control and centralized management. When the relevant parameters in the circuit are abnormal, the monitoring equipment will send out an audible and visual alarm to indicate the alarm position. At the same time, the on-site detector will send out an audible and visual alarm and control signal to remind the user to check or replace the hidden circuit, so as to reduce the risk of fire caused by electrical reasons. Taking comprehensive electrical application as the development center, Sfere Electric will become a top electrical application solution expert. It is the vision of the enterprise to better serve China's intelligent factory and fulfill the social responsibilities.

    2023 09/20

  • Application of Communication Gateway in EMS
    With the widespread application of intelligent equipment, the automation level of power distribution system is increasing. In order to make full use of the equipment capacity and improve the security, reliability and stability of the distribution system, users need to configure a matching power monitoring system for centralized and efficient management. As the middleware of the monitoring system, the communication gateway can be widely used in the integrated automation system of power plants, substations, centralized control stations, distribution network sub station/master station system, regional power grid dispatching automation, airport, tunnel, highway and other power monitoring and other electromechanical centralized control systems. 01 Communication gateway SC series SC series wireless communication modules support transparent transmission modes of LoRa, NB-loT, 4G and RS485. LoRa communication gateway uses serial port to transmit and receive data, which reduces the threshold of wireless applications and enables one-to-one or one-to-many communication. Among them, the SC2 LoRa communication module is widely used, and its characteristics are as follows: Wireless transparent transmission Long distance Low power consumption Disconnection self-recovery Support multiple frequency bands No additional data traffic costs Technical parameter 02 Communication gateway S15 S15 gateway is a small gateway device that can collect multiple communication protocols and upload data to the cloud platform or on-site monitoring system. Its supporting SmartHMI (SmartHMI: Sfere Universal Small Gateway Configuration Tool) supports the configuration of the connected devices, monitoring their data or debugging. It is mainly used to collect data of intelligent measurement and control, power quality and electrical safety products. The uplink communicates with the monitoring system through the Ethernet port, and uploads to the cloud platform through 2G, 4G and NB loT wireless methods. The downlink realizes wired/wireless networking through RS485 or LoRa. Characteristic Wireless networking Rich communication protocols Intelligent configuration and debugging Dual network port switching function Device management Technical parameter&Model selection 03 Communication Gateway S12 S12 gateway is a small gateway device that can collect multiple communication protocols and upload data to the local monitoring system. Its supporting SmartHMI (SmartHMI: Sfere Universal Small Gateway Configuration Tool) supports the configuration, monitoring or debugging of the connected devices. It is mainly used to collect data of intelligent measurement and control, power quality and electrical safety products, realize Modbus RTU or DL/T645 communication through RS485 for the down side, and realize Modbus TCP communication with the local monitoring system through Ethernet port for the up side. Characteristic Device management Intelligent configuration and debugging Dual network port switching function Technical parameter 04 Communication Gateway S20 S20 is a universal communication gateway facing the industrial control field. It has multiple functions such as multi-channel data acquisition, multiple protocol conversion, data analysis and calculation, automatic logic control, connection to various platforms, and WEB flexible configuration. Characteristic Device management Data calculation Protocol conversion Offline cache History record Technical parameter Reasonable and effective use of the gateway can obtain information from equipment and other links, provide real-time data to the power monitoring system (improve the practicability and effectiveness of information), and can timely conduct remote development and maintenance, provided that you have appropriate security clearance authority. In addition, due to the wide variety of industrial Ethernet protocols, information may need to be converted and conversed between multiple protocols. Some industrial-grade gateways can realize the interactive transmission of information between wired protocols and wireless protocols.

    2023 09/05

  • good news! Our company has obtained the laboratory accreditation certificate of China National Accreditation Service for Conformity Assessment (CNAS)
    In August, the central laboratory of Jiangsu SFEER Electric Co., Ltd. officially passed the accreditation of China National Accreditation Service for Conformity Assessment (CNAS) and obtained the laboratory accreditation certificate. CNAS certification CNAS certification, the full name of China National Accreditation Service for Conformity Assessment (China National Accreditation Service for Conformity Assessment), is the only authoritative organization for laboratory accreditation in China, and its laboratory accreditation is regarded as technical ability and management at home and abroad. Based on the reliability of its capabilities, it has high authority and credibility in the world. China National Accreditation Service for Conformity Assessment Laboratory Accreditation Certificate Passing the CNAS accreditation marks that the hardware conditions, management level and professional technical ability of our laboratory have reached a relatively advanced level. At the same time, it ensures that the test report issued by the laboratory is notarized and valid, and improves the credibility of the test report. Our company is a technology-innovative enterprise focusing on providing systematic solutions for smart grid users. Based on a sound management system, we provide customers with a complete and reliable cooperation platform with innovative research and development, high-quality products and efficient services. In the new era of quality-oriented development, our central laboratory will take the CNAS accreditation as a starting point to further improve the company's competitiveness and popularity, improve the quality management and comprehensive management level for the laboratory, and continue to improve the level of electrical inspection and testing. Provide technical support and escort for the company's products, and make positive contributions to the company's high-quality development!

    2023 08/25

  • Smart Meter Application Accelerates Power Meter Change
    Unlike conventional meters, as an effective link between the power grid and the home, smart meters are more user-friendly and safer. With the introduction of smart meter replacements in various regions, the degree of penetration will increase, and quantitative changes will result in qualitative changes. Causes power change. State Grid Corporation of China held a working conference in 2014 and clearly stated that it plans to install 60 million new smart meters in 2014, which is more than double the planned amount in 2013. According to reports, the 2013 State Grid Working Report at the beginning of last year required the application of modern technologies such as the Internet of Things and cloud computing to build a new generation of smart substation demonstration projects, and promote distributed power grid connection, smart grid control systems, and distribution automation. . Installed 30 million smart meters and new electricity meters, and converted 3 million electric meters. Comparing the two-year work plan, we can see that in 2014, we quantified the work goal of building a new generation of smart substations and intelligent transformation of substations, while the installed capacity of smart meters increased from 30 million to 60 million. With the development of electronics, information, software, communications, and electromechanical control technologies, the output of electronic energy meters in China has now become an absolute advantage and is gradually replacing the existing inductive energy meters. The development of related technologies has promoted the continuous upgrading of electrical instrumentation product technology. Some industry analysts believe that in 2016 China's smart grid will enter the stage of improvement, and some old and old meters will be upgraded. Therefore, after 2016, China's smart power meter market will continue to grow substantially. At present, China's smart energy meter technology, manufacturing level and application level of the world's leading position. With the continuous advancement of the international smart grid construction, the market demand for smart energy meters has rapidly expanded. The demand for global smart grid construction will form a vast smart energy meter market, bringing new opportunities for the development of China's electric energy metering industry. In order to strengthen the management and control of the quality of smart meters, it is expected to implement a number of new technical standards in the third quarter, including a new standard system for smart meters, which consists of 12 types of specifications: functional specifications, technical specifications, type specifications, and safety certification specifications. Standard composition. This standard system has detailed regulations on metering, fee control, communication, power consumption, and even the wiring and appearance of electronic circuits, and has put forward higher requirements. By then, all meter manufacturers must adopt new practices. In order to prevent the market from possible turbulent, more stringent requirements only involve the sample delivery procedure. The entire smart meter semiconductor market is reshuffled. Even before these new standards were issued, almost all smart meter semiconductor manufacturers had adjusted their product strategies to prepare for the new standards.

    2023 08/16

  • Application of Elecnova Products in Dongfeng Honda Auto Parts Co Ltd
    01 Company Profile Dongfeng Honda Auto Parts Co., Ltd. is mainly engaged in the production of key parts for engines and chassis of Honda series cars. It is an important parts production base for Honda passenger vehicles in China. The products involve camshafts, connecting rods, crankshafts, cylinder liners, front and rear knuckles, fork arms, front and rear brake discs, etc., and are mainly used for the Honda train models produced by Dongfeng Honda Motor Co., Ltd., Guangqi Honda Co., Ltd., Honda Motor (China) Co., Ltd. and overseas companies. 02 General situation of the project Jiangsu Sfere Electric Co., Ltd. undertakes the intelligent monitoring and energy management system engineering of this project, which consists of three parts: intelligent power monitoring system, energy management system, and electrical fire monitoring system. These three parts are three relatively independent systems, each with its own independent hardware and running software. The intelligent power monitoring system, energy management system, and electrical fire monitoring system can achieve data sharing through network connection. It can automatically collect and intelligently manage the electric energy information of all kinds of metering points in the switching station and power distribution rooms of the whole plant, so that the distribution network can operate in a safe, reliable, high-quality and efficient state, realize the remote measurement, control and management of the distribution network, and realize the demand for power safety, power management, energy conservation and consumption reduction. Through the centralized collection and analysis of water, electricity, and gas, the user's energy consumption is segmented and analyzed to form intuitive data and charts, achieving remote meter reading functions and comprehensive energy management covering energy plan management, energy performance management, energy balance management, energy statistical analysis reports, and other functions. By monitoring parameters such as residual current and load current in the circuit, alarm and monitoring of the protected electrical circuit can be achieved, and it can be uploaded to the fire monitoring system for centralized control and management. 03 Specific configuration situation On the drawings, the circuits of the power distribution cabinets in each power distribution room that need to install power monitoring instruments are equipped with multifunctional power meters PD194Z-9HY and integrated protectors to monitor the current and voltage of a single circuit in real time, and then connect them to the respective power distribution rooms communication management machine. After the system is completed, the communication management machines in each power distribution room are pulled to the main control room of the main building through optical fiber converters, and all monitoring data is transmitted to the SFERE3000 power monitoring system. Other equipment with digital communication interfaces, such as transformer temperature control equipment, DC equipment, and analog screens, need to upload data to the background computer for remote monitoring or control. 04 Network Topology Diagram Structure The overall network acquisition structure of the system is based on the fiber optic TCP/IP network communication between each distribution room and the main control room of the main building, to complete centralized data collection and processing. The network is divided into upper layer network and lower layer network. The upper layer network refers to the Ethernet (or fiber optic Ethernet) from each sub station to the control center. Industrial grade fiber optic transceivers are used for photoelectric conversion between optical fibers and various management devices. The underlying network consists of RS485 communication cables between instruments, protection and other devices, which are laid using dedicated twisted pair cables. Due to the configuration of communication management machines in their respective sub stations, RS485 transmission distances are all within the sub stations, and long-distance signal interference and attenuation issues will not occur. The on-site equipment layer of the network mainly includes measuring instruments, protection devices, etc., which are installed locally in the corresponding switchgear, have local operation functions, and are not affected by remote computer startup and shutdown. This system is divided into three layers from bottom to top: device terminal layer, network communication layer, and system management layer. 05 Implement functions It can automatically collect and intelligently manage the power information of various metering points in the high voltage power distribution room and low voltage power distribution room of the whole plant, so that the distribution network can operate in a safe, reliable, high-quality and efficient state, realize remote measurement, control and management of the distribution network, and meet the requirements of power safety, power management, energy conservation and consumption reduction. By monitoring parameters such as residual current and load current in the circuit, alarm and monitoring of the protected electrical circuit can be achieved, and it can be uploaded to the fire monitoring system for centralized control and management. When the relevant parameters in the circuit are abnormal, the monitoring equipment emits an audible and visual alarm to indicate the alarm location. At the same time, the on-site detector emits an audible and visual alarm and control signal to remind users to investigate or replace hidden circuits, reducing the risk of fire caused by electrical reasons. About Elecnova/Sfere Electric Elecnova / Sfere Electric a leading manufacturer and solution provider of Power quality analyzer / Energy analyzer / kWh energy meter / Multi circuit power monitoring system / EV charger metering / Digital power meter / Motor controller / Busway temperature sensor / Harmonic Filter / Power factor correction / Low Voltage power distribution panel / Cloud view Power monitoring system.

    2023 07/20

  • Application of Sfere Power Quality Products in Supercomputing Center
    The supercomputing center is built on the basis of supercomputers to solve large and complex problems that cannot be completed by ordinary computers and servers. Compared with the early computing center, its computing capacity has made a huge leap, and its applicable fields and usage patterns have been greatly expanded. The supercomputing center is built on the basis of sufficient scientific and technological innovation capabilities and application needs, and is a concrete manifestation of a country's and region's independent innovation capabilities and comprehensive competitiveness. Large data centers have high requirements on the power supply stability of supercomputing rooms. There are a large number of UPS and switching power supplies in the communication system. While improving the power supply stability of computer rooms, such equipment will generate large 5th, 7th and 11th harmonics. Sometimes, UPS incoming line switches trip for no reason and communication is disturbed. In a domestic supercomputing center, when eliminating the harmonic hazard in the computer room, the SFR-APF active power filter was used to treat the UPS locally, which can greatly reduce the harmonic current distortion rate, effectively solve the problem of circuit breaker tripping and communication interference, and improve the reliability of power supply. In addition, SLG series harmonic elimination reactive power compensation products are used in the distribution room for centralized harmonic control, and PD194Z-9CY multi-function harmonic meter is also equipped for power quality monitoring. Operating principle of active filter CT is used to collect the load current signal, and the harmonic part is separated through the internal detection circuit, and then the PWM signal is sent to the internal IGBT power converter to generate a compensation current with the same magnitude and opposite phase as the system harmonic, realizing the real-time dynamic filtering function. Product characteristics 01Flexible application scheme Modular design, convenient for expansion, supporting 16 modules in parallel. Support rack mounted or wall mounted installation, and adapt to a variety of installation environments. Support three-phase three wire or three-phase four wire, redundant N-wire terminal blocks, and adapt to the site environment to the maximum extent. CT installation position is flexible, both power side and load side can be used. 02Excellent filtering performance The maximum filtering times are 51, and the harmonic filtering rate is greater than 97% Multiple compensation modes can be selected to realize on-demand distribution of active filter, reactive power compensation and unbalanced current compensation Full range reactive compensation Perfect three-phase imbalance strategy to realize active/reactive/split phase imbalance compensation Three level main circuit, lower power consumption and higher efficiency The full response time is less than 5ms, and the control is faster, which is conducive to improving the transient stability 03Complete equipment and system protection External electrical fault protection of equipment, including bus short circuit, voltage overvoltage and undervoltage, overvoltage and underfrequency, phase sequence error, current reverse sequence, etc Internal fault protection of equipment, including over-current protection, IGBT overheating protection, etc Automatic capacity reduction when the working environment exceeds the limit Software and hardware current limiting Resonance avoidance, automatically away from the system resonance point 04Humanized human-computer interaction experience Interactive optional 7-inch or 10-inch LCD touch screen SLG series harmonic elimination reactive power compensation module SLG series harmonic elimination reactive power compensation component is a filter circuit composed of a filter reactor with a certain reactance coefficient and a capacitor with a certain capacity in an appropriate proportion to achieve reactive power compensation and harmonic control. PD194Z-9CY multi-function electric instrument PD194Z-9CY multi-function electric instrument can monitor a variety of electrical parameters, such as voltage, current, frequency, power, power factor, electric energy, demand, etc., and has the functions of switch status monitoring, limit exceeding alarm, analog output, electric energy pulse, communication, etc. As an advanced intelligent and digital power grid front-end acquisition component, the instrument can be used in energy management systems, power distribution automation, intelligent buildings and intelligent switchgear; With a variety of wiring methods, it is convenient to use and can meet various requirements on site.

    2023 07/12

  • On-site energy monitoring system Sfere3000 applies at the small industrial and commercial projects
    Why need the small local EMS system? Since the wireless data transmission technology has fast growing in recent years which makes the possibility of the cheap and reliable data transmission provide by the web serve operator comes true. In this regard, many of the Cloud base power management software or energy management software were launched in the power distribution industry. With comprehensive software design and mature communication and data acquisition devices deployment, Cloud based PMS can dramatically improve the management efficiency and reduce human operation and maintenance costs in a long term prospect for those multi project management activities. Meanwhile, a large number of small and medium-sized enterprises and business entities may not have as much multi project management demand, and those enterprises may not be able to afford the cost of devices deployment and server installation. For those projects scale is small with less monitoring devices, and short distances, what other options can they have besides cloud based power monitoring systems? Is it possible to have an on-site rather than Cloud based power monitoring system that can be developed based on the existed software, communication, and other technologies to improve the safety, reliability, and stability of power transformation and distribution system operation. Is there a management software can meet the all-need monitoring of the environment of 35kV and below voltage level power transformation and distribution systems, accelerated the digitalize and information internal sharing of the energy consuming enterprises, reduce operating manpower costs, improve production efficiency, speed up the response to abnormalities in the process of power transformation and distribution, and enhance the power supply and distribution service guarantee capability? Sfere Electric heard the voice from the market and its R&D team has brought SFERE3000 power monitoring software, providing a cost-effective small power monitoring and operation system for the industry. Where the On-site PMS goes for? - For short distance The distance data transmission is not far. The physical distance between the power distribution room and the monitoring center is within 2kms. Communication deployment can achieve data transmission through LAN cables or fiber-optical. - For small project The scale of the projects are small which running industrial processing, mining ,transportation, hospitals, schools, and commercial centers enterprises. The capacity of transformers in electricity consuming enterprises and the and for voltage level is below 35KV for the new build or renew purpose for the expansion of power transformation and distribution systems. - For energy consumption management The requirements for power monitoring are mainly aimed at the consumption and management of energy, including specific recording and export of energy consumption reports.Further more, the software could make trend analysis of energy consumption and do the event recording and alarm. Device deployment of the EMS As can be seen from the equipment deployment of the SFERE3000 energy monitoring system in above. The SFERE3000 EMS can monitor the operation status and equipment of various levels of high voltage, low voltage, and terminal distribution systems in real time. Providing various of power and ambient monitoring, power consumption analysis, power consumption reports, abnormal alarms and records, remote control, etc. As far as the structure is concerned, the system can be divided into three layers: Data acquisition layer, Data transmission layer, Data management layer. Data acquisition layer:Various monitoring hosts, protection devices, measuring instruments, sensors which installed on site to achieve independent real monitoring and data transmission. Data transmission layer:gateways,communication concentrator, and other network devices achieve unified data acquisition, fault tolerance, calculation, forwarding, and network transmission . Data management layer:systematic workstation, monitoring software etc; HMI for various data monitoring, storage, processing, and alarm purpose. What about the functionality of SFERE 3000? Real time measuring Display the main electrical parameters, energy consumption statistics, switch status, and other information that users are concerned about at each site of the project at the monitoring or control center. Systematic drawing display Display various main electrical parameters and switch status information of the system operation through a system diagram interface, and respond to various limit exceeding alarms and status change alarms. Display various electrical parameters, switches on/off status of the power system along with the primary systematic drawing. Energy consumption report Query, print, and export the real-time and historical energy operation data, as well as energy consumption statistics data within any historical time period. Trend analysis Create curve accordance with the various parameters during the equipment operation to analyze the reliability of the equipment operation over a certain period. Alarm and notification Support parameter settings for remote measurement threshold crossing and remote signal switch displacement, and achieve real-time alram information push and record query. Data forwarding Supports forwarding data to third-party management systems and platforms by LAN or RS485 interfaces and supports standard protocols such as Modbus RTU/TCP, IEC104, MQTT, OPC, etc. Configuration - By providing comprehensive and real-time monitoring, historical report query, trend curve analysis, alarm threshold setting, alarm notification query, data forwarding and other functions for the distribution room, distribution circuit, and distribution equipment, the safety, reliability, and intelligence level of the power transformation and distribution system are significantly improved. - Multi-channel data collection, multi-protocol conversion, data analysis and calculation, automatic logic control, multi-platform connection, WEB flexible configuration. - Add one 4G wireless channel based on the S20C8. - Collect data of intelligent measurement and control, power quality and electrical safety products, communicate with the monitoring system via Ethernet port on the uplink, and upload to the cloud platform via 2G, 4G and NB loT wireless modes. Downlink wired/wireless networking through RS485 or LoRa. - Collect data of intelligent measurement and control, power quality, electrical safety products, realize Modbus-RTU or DL/T645 communication through RS485 for the down side, and realize Modbus-TCP communication with the local monitoring system through Ethernet port for the up side. - It has powerful functional integration: integrating multiple functions such as protection, measurement, control, monitoring, communication, fault recording, event recording, etc. High precision measurement of current, voltage, power, power factor, frequency, zero sequence current, zero sequence voltage, and calculation of electrical degree; Online recording of 256 events, which are not lost after power failure. - It has functions such as dynamic simulation diagram, live display and locking, temperature and humidity control, circuit breaker opening and closing status indication, energy storage indication, grounding switch status indication, car position indication, human induction live prompt and cabinet lighting, voice error prevention prompt, remote/local operation, bus/contact temperature measurement, remote communication, etc. Measurement of three-phase current, three-phase voltage, active, reactive, power factor and other parameters, as well as electrical energy metering functions. - Capable of precise power parameter measurement, comprehensive power metering, and power quality analysis; It is equipped with abundant I/O modules for condition monitoring and control of on-site equipment, which can be easily integrated with various intelligent distribution systems and energy management systems, and share abundant monitoring data and power quality data. - Large color screen centralized acquisition host, embedded/wall mounted installation, color LCD display, built-in wireless receiving module, 200 event records, alarm output, RS485 communication. - Temperature sensor for temperature measurement. - Full modular design, flexible combination; At the same time, the intelligent monitoring module can automatically adjust the output ratio of passive module according to the dynamic requirements of the system, and meet the requirements of supplementary. Switching mode adopts dynamic output, smooth and stable, neither filling nor underfilling. The external monitoring unit can comprehensively monitor the real-time status of the capacitor, avoid the capacitor "working with disease" and extend the service life. - Faster response time, full response time ≤ 10ms, dynamic continuous smooth compensation, and high-speed response speed, which has good dynamic compensation effects; Adopting a fully interactive 7-inch touch LCD and supporting backend monitoring software to meet the different needs of users. - Harmonic compensation, reactive power compensation, and harmonic reactive power compensation, with multiple uses for one machine; Equipped with harmonic fractional compensation function, capable of setting reactive power compensation ratio; Hd 7 inch color touch screen, with real-time display of system and device operating parameters on the screen; Response speed: ≤ 5ms; Can filter out 2-51st harmonics; And support backend monitoring software to meet the different needs of users. - Equipped with functions such as full power parameter measurement, energy metering, and power quality monitoring, with RS485 communication interface, supporting Modbus RTU and DL/T645 communication protocols, and can be connected to various power monitoring systems and energy management systems. - Din rail mounted, capable of measuring 4-circuits three-phase or 12-circuits single-phase power parameters, optional switch module for switch status detection, limit exceeding alarm, and 4G communication module. - Capable of precise power parameter measurement, comprehensive power metering, and power quality analysis; It is equipped with abundant I/O modules for status monitoring and control of field equipment, which can be easily integrated with various intelligent distribution systems and energy management systems, and share abundant monitoring data and power quality data. Dot matrix LCD. - Integrate HMI, switching power supply, intelligent gateway, Lora module, etc; Wall-mounted on-site centralized display. - 1 uplink Ethernet interface; 1 uplink WIFI interface (optional); 1 uplink 4G interface (optional); 2 Downlink RS485 interfaces, capable of connecting 64 temperature measurement modules; 1 downlink LoRa interface (optional); Embedded web server. - LoRa and RS485 transparent transmission, LoRa transmission power 1W. - 6 temperature measurements; Temperature measurement range -20~150 ° C, accuracy ± 1 ° C; Real time, average, interval temperature, temperature rise rate; Temperature limit exceeding warning and alarm SOE. - Temperature sensor - The universal circuit breaker is suitable for distribution networks with AC 50Hz, rated voltage of 690V and below, and rated current of 200A-6300A. It is used to distribute electrical energy and protect lines and power equipment from overload, undervoltage, short circuit, single-phase grounding and other faults. It has intelligent protection function, precise selective protection, can improve power supply reliability, and avoid unnecessary power outages. Equipped with an open communication interface, it can perform "four avoidance" to meet the requirements of the control center and automation system, with isolation function. - Plastic case type circuit breaker is suitable for AC 50/60HZ, rated insulation voltage to 1000V, rated working voltage 415/690V, rated working current to 800A circuit for infrequent conversion and motor infrequent starting (lnms400A and below). Equipped with overload and short circuit protection functions, it can protect the circuit and power equipment from damage. Small size, high breaking capacity, short flashover, and anti vibration. Can be installed vertically (i.e. vertically) or horizontally. - The isolation switch is suitable for circuits with AC 50Hz, rated voltage 400V and below, and rated current 16A-1600A. Used for infrequent manual connection and disconnection of circuits, 690V products are only used for electrical isolation. - SFP1 series ATSE consists of two parts: the switch body and conversion control. The switch is driven by a motor and electromagnetic coil, with fast conversion speed. The power supply for the conversion controller is commonly used, and the backup power supply is AC220V as the working voltage. - Mini-circuit breakers are suitable for places with AC 50Hz or 60Hz, rated voltage of 400V and below, and rated current of 6A-63A. Mainly used for overload and short circuit protection of lighting, distribution lines, and equipment in office buildings, residential buildings, and similar buildings. It can also be used for infrequent line switching under normal circumstances. - Intelligent miniature circuit breaker is a new type of IoT circuit breaker, suitable for AC 230V/400V, 50HZ distribution networks. Mainly used to link the load at the end of the line, to connect and disconnect the line, and to avoid injuries and losses caused by safety hazards such as overvoltage, undervoltage, overload, leakage, and overheating of operating equipment. This product integrates multiple functions such as remote control, data measurement monitoring, and security status monitoring. It is a multifunctional IoT product that achieves intelligent power management and control of application environments such as homes, buildings, public treasures, streetlights, and municipal engineering. - The control and protection switchgear adopts a modular single structure, integrating the comprehensive functions of circuit breaker (fuse), contactor, overload (overcurrent) protector, overvoltage/undervoltage, phase loss protector, voltmeter, ammeter, residual current protection, isolator and other electrical elements. Application of MCU digital processing technology, high measurement accuracy, good linearity, accurate and reliable fault resolution, and strong anti-interference ability.

    2023 06/26

  • Hazards to Power Capacitors
    (1) Hazards to Power Capacitors When there is a harmonic in the power grid, the terminal voltage increases after the capacitor is inserted, and the current through the capacitor increases more, which increases the power loss of the capacitor. For film-membrane composite dielectric capacitors, although the power loss when harmonics are allowed is 1.38 times the power loss without harmonics, the power loss when harmonics are allowed for all-film capacitors is 1.43 times that without harmonics, but if Higher harmonic content, beyond the capacitor allowable conditions, will make the capacitor over-current and overload, the power loss exceeds the above value, so that the capacitor abnormal heat, the insulation medium under the effect of the electric field and temperature will accelerate aging. Especially when the capacitor is put into the power grid where the voltage has been distorted, the harmonic of the power grid may also be exacerbated, that is, the phenomenon of harmonic expansion occurs. In addition, the presence of harmonics tends to make the voltage appear sharp. The steep-peak voltage wave easily induces partial discharge in the medium. Due to the large voltage change rate and partial discharge intensity, it can accelerate the aging of the insulating medium, thus shortening it. The service life of the capacitor. In general, for every 10% increase in voltage, the life of the capacitor is reduced by about 1/2. In addition, in the case of severe harmonics, the capacitor will bulge, breakdown or explosion. (2) Harm to Power Cables As the frequency of harmonics increases, the skin effect becomes more significant as the cross-sectional area of the cable conductor increases, resulting in an increase in the AC resistance of the conductor and a decrease in the allowable passing current of the cable. In addition, the resistance of the cable, the system bus side and the line inductance are connected in series with the system, and the capacitance and resistance of the capacitor and line used to increase the power factor are connected in parallel with the system, and resonance may occur under a certain value of inductance and capacitance. (3) Hazardous harmonics to the power transformer increase the copper loss of the transformer, including resistive losses, eddy current losses in the conductor, and stray losses due to leakage flux outside the conductor. Harmonics also increase the iron loss of the transformer, which is mainly manifested in the increase of the hysteresis loss in the core, and the worse the waveform of the voltage caused by the harmonics, the greater the hysteresis loss. At the same time, because of the increased loss in the above two aspects, it is necessary to reduce the actual capacity of the transformer, or to consider the harmonic content of the grid when selecting the rated capacity of the transformer. In addition, harmonics also cause the transformer noise to increase. The vibration and noise of the transformer is mainly caused by the magnetostriction of the iron core. With the increase of the number of harmonics, the components with the vibration frequency around 1KHZ increase the mixed noise. Also emits metal sounds. (4) Hazards to Electric Motors Harm to Electric Motors The influence of harmonics on asynchronous motors is mainly to increase the additional loss of the electric motor, reduce the efficiency, and cause the electric motor to overheat when it is severe. In particular, negative-sequence harmonics generate a negative-sequence rotating magnetic field in the motor, forming a torque opposite to that of the motor, and acting as a brake, thereby reducing the output of the motor. In addition, the harmonic current in the motor will cause the motor to generate mechanical vibration when the frequency is close to the natural frequency of a certain part, which will cause great noise. (5) Hazards to low-voltage switchgear For circuit breakers used in power distribution, all-magnetic-type circuit breakers are susceptible to harmonic currents, which increase iron loss and generate heat. At the same time, they are affected by the influence of electromagnets and eddy currents. The tripping is difficult, and the higher the number of harmonics is, the greater the influence is; the thermal magnetic type circuit breaker, due to the collector skin times of the conductor and the increased iron consumption, causes the heat generation, which causes the rated current to decrease and the tripping current to decrease; the electronic type circuit breaker The harmonic current also has to reduce its rated current, especially the electronic circuit breaker that detects the peak, and the rated current is reduced more. It can be seen that the three types of power distribution circuit breakers described above may be generated due to harmonics. For leakage circuit breakers, due to the effect of harmonic leakage currents, the circuit breakers may be abnormally heated and cause malfunction or failure. For electromagnetic adapters, the harmonic currents increase the temperature rise of the magnet components, affecting the contacts, and the coil temperature rises to lower the rated current. For thermal relays, the rated current is also reduced due to harmonic currents. They can all cause malfunctions at work. (6) Interference to low-voltage system equipment For weak equipment such as computer networks, communications, cable television, and alarm and building automation, the harmonics in the power system are coupled to these systems through electromagnetic induction, electrostatic induction, and conduction to generate interference. The coupling strength between the induction and the electrostatic induction is proportional to the interference frequency. The conduction is coupled through the common ground. A large amount of unbalanced current flows into the grounding pole, thus interfering with the weak current system. (7) Impact on the accuracy of power measurement The currently used power measurement instruments are magneto-electric and inductive. They are greatly affected by harmonics. Especially the electric energy meter (adopts the induction type more), when the harmonic wave is bigger, will produce the measuring confusion, the measurement is not accurate. (8) Harmonic effects on human body From the aspect of human physiology, when human cells are stimulated and excited, they will rapidly fluctuate or reversibly flip on the basis of the resting potential of the cell membrane. If the frequency is close to the harmonic frequency, the grid Harmonic electromagnetic radiation will directly affect the human brain magnetic field and the magnetic field. When the harmonic pollution degree of the power grid is less than the national standard, it usually does not affect the system. As the degree of pollution increases, the influence of harmonics gradually emerges. In the case of severely exceeded harmonics, serious harmonic consequences will occur if harmonics are not controlled. The characteristics of harmonic sources are very complex, because the generation of harmonics depends not only on the load itself that generates the harmonics, but also on the short-circuit capacity of the grid, the composition of the grid, and the nature of other loads in the grid.

    2023 06/16

SEE MORE

Email to this supplier

-
SEND

Browse by: All Products | China Suppliers Service is provided by Bossgoo.com

Copyright © 2008-2024 Bossgoo Co., Ltd. All rights reserved.

Your use of this website constitutes acknowledgement and acceptance of our Terms & Conditions